Specify the Airside Surface for Cleaning and Inspection

Plan the aluminum facing, sealed joints and inspection access for your pre-insulated ductwork. If the project specifies antibacterial performance, share the tender clause so we can check which reports and samples are available for the proposed facing.

UNTDuct pre-insulated duct with embossed aluminum lining and a joining profile being fitted

Specify a Cleanable Facing or a Tested Antibacterial Facing

Cleanable Aluminum Facing

Specify the finish, edge closure and joint details. Confirm the access needed for inspection and the cleaning method allowed by the project.

View the AluPIR board

Facing With a Specified Antibacterial Result

Where the tender specifies antibacterial performance, identify the exact facing and treatment. Request a report for that specimen and agree how any cleaning or ageing exposure will be assessed.

Check the submittal requirements

Hygienic Ductwork Specification Checklist

Use this checklist to record the requirements for each duct run and confirm which drawings, samples and reports are needed before submitting the proposed system.

Specification Item What to Record What to Review
Duct service and location Supply or return air, room or zone, and duct run reference. Latest duct schedule and relevant drawing.
Airside facing Smooth or embossed finish, foil thickness, and any specified surface treatment. Facing sample and product datasheet for the proposed finish and treatment.
Panel core and thickness PIR or phenolic, panel thickness, and the temperature and humidity conditions used to assess condensation risk. Panel datasheet and insulation and joint details.
Joints and inspection access Joining profile, cut-edge closure, tape, sealant and access points. Joint and access details with the proposed accessory references.
Cleaning procedure Method, frequency and, where chemicals are used, agent, concentration and contact time. Written compatibility guidance for the facing, tape and sealant.
Surface test requirements When specified, record the method, acceptance criteria and any cleaning or ageing exposure required by the tender. Report identifying the exact tested specimen and conditions.

Four Details That Affect Duct Hygiene

Surface Treatment

Antibacterial performance depends on the treatment at the exposed surface. Check the specific facing and reported test conditions before applying a result to the proposed board.

Airside Material and Edge Closure

In intact aluminum-faced construction, the air stream contacts the foil facing. If exposed fibrous lining is restricted, verify the whole airside assembly, including cuts, joints and access openings.

Insulation and Moisture Control

Closed-cell cores provide insulation within the panel. Review dew-point conditions, insulation continuity and moisture exposure around joints and supports to assess condensation risk.

Cleaning and Inspection Access

Check access to fittings, equipment interfaces and sections that need inspection. Match the proposed facing, tape and sealant to the cleaning method and chemicals in the maintenance plan.

Match Each Hygiene Requirement to the Right Evidence

Use the edition and acceptance criteria in the project specification. Ask for evidence covering the exact product, construction or space being assessed.

Method or Guidance What It Covers What to Request
ISO 22196 / JIS Z 2801 Antibacterial activity on a specified surface specimen. Ask for the exact facing, test method, organisms, contact time and reported result.
ASTM G21 Fungal resistance of synthetic polymeric materials under the test conditions. Where applicable to the proposed material, request the specimen description and observed growth rating.
VDI 6022 / EN 15780 Ventilation-system hygiene and cleanliness criteria, respectively. Confirm the applicable inspection, access, cleaning and handover requirements.
ASHRAE 62.1 / ASHRAE 170 Ventilation design requirements under their respective scopes. Confirm which standard and edition the project adopts. For healthcare spaces, check the applicable room requirements.
ISO 14644-1 Air cleanliness classification by airborne particle concentration. Confirm the cleanroom acceptance criteria and keep room qualification separate from facing test reports.

View UNTDuct certificates and published test documents

Compare Airside Construction Before You Specify

Compare both duct options against the same air service, cleaning procedure, access requirements and operating conditions.

Design Check Aluminum-Faced Pre-Insulated Duct Internally Lined Galvanized Steel Duct
Airside construction Intact foil forms the airside surface. Verify sealed edges, joints and penetrations. Check whether the liner contacts the air stream and how its surface and cut edges are protected.
Cleaning and access Confirm the selected finish, joint materials and access against the planned cleaning method. Use the liner manufacturer's cleaning guidance and verify access and surface condition.
Moisture and condensation Check insulation thickness, joint continuity and external exposure for the design conditions. Check liner and insulation details, humidity exposure and condensation risk at the same conditions.
Joints and transitions Specify profile, sealant, edge closure and equipment connections on the drawings. Specify lining terminations, flange details, transitions and the required joint sealing.
UNTDuct AluPIR board showing the aluminum facing and foam core UNTDuct aluminum-faced phenolic duct panel

Specify Facing and Core Separately

Compare smooth and embossed samples using the planned cleaning method. Specify the facing finish and thickness separately from the foam core. Select PIR or phenolic according to the project's thermal, fire and construction requirements.

View PIR panels · View phenolic panels

Taping a pre-insulated duct section during fabrication

Detail Joints and Equipment Interfaces

Identify the profile, tape, sealant and cut-edge treatment on the approved detail. Where the specification calls for fungal-resistant sealant or wet cleaning, verify the exact accessory and its documented compatibility.

View joining profiles · View aluminum foil tape

Example: Prepare a Pharma Supply Duct Submittal

A pharmaceutical project specifies routine wipe cleaning for a supply branch downstream of a filter housing. Before releasing the material list, check the proposed construction against the cleaning and inspection requirements.

Confirm the Cleaning Method

Check the proposed facing, tape and sealant against the specified agent, concentration, contact time and cleaning frequency. Resolve any compatibility gaps before finalizing the material list.

Mark the Filter Connection

Show the housing interface, joint detail and inspection opening on the drawing. Check that the opening remains accessible after installation.

Match the Report to the Facing

If the tender requires antibacterial performance, check that the report identifies the facing and treatment proposed for that duct run.

Send Your Duct Schedule and Cleaning Specification

Share your tender clause and marked-up drawings. We can review the facing, joint accessories and documents needed for your submittal.

Include These Project Details

  • Duct service, installation location and drawing revision
  • Required airside finish, board construction and joint details
  • Cleaning agents, frequency and moisture exposure
  • Specified test methods, sample needs and estimated quantities

Review Ductwork by Application

Review fire-test documentation for separate fire requirements

Hygienic Ductwork FAQs

How long does an antibacterial facing remain effective?

Ask for performance evidence for the exact facing before and after the specified cleaning or ageing exposure. A result for a new specimen does not establish performance after repeated cleaning.

Can I clean aluminum-faced ducts with chemical disinfectants?

Share the chemical name, concentration, contact time, method and frequency. Check compatibility for the facing, tape and sealant before approving the cleaning procedure.

What should I specify at duct joints and access openings?

Identify the joint profile, edge closure, sealing material and access opening on the drawing. Verify that the selected detail allows inspection and the cleaning method specified for the run.

Should I choose a smooth or embossed foil facing?

Compare samples of the proposed finishes against your cleaning method, handling conditions and panel requirements. Request the finish and treatment as separate items on the submittal.

Does a surface antibacterial report establish a cleanroom class?

Surface testing describes the tested specimen and conditions. ISO 14644-1 classifies air cleanliness by airborne particle concentration in the cleanroom or clean zone.

Can I request samples and test documents for a tender?

Yes. Send the facing specification, cleaning conditions and required test documents. We can confirm available samples and reports for the proposed construction.

Request Test Documents and Facing Samples

Include the duct service, required facing finish or treatment, cleaning method and any test methods or acceptance criteria in your tender. We can confirm which reports and samples are available for the proposed facing. Email drawings or tender clauses to inquiry@untduct.com with the project name in the subject.

 
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!