Pre Insulated Duct Fire Rating

Pre Insulated Duct Fire Rating

Details
Pre-insulated duct fire rating is a core indicator for evaluating ventilation systems' fire safety. Specifically designed for commercial buildings, industrial facilities and public spaces, it ensures key passage integrity under fire conditions.
Category
UNTDuct PIR System
 
Send Inquiry
Description
Technical Parameters

 

Pre insulated Duct Fire Rating Description

 

The Pre insulated Duct Fire Rating does not depend on a single material, but is achieved through three technical measures: "core material formula + surface layer protection + structural optimization".

 

Fire-retardant modification of core material (core foundation)PIR/PUR core material: Phosphorus-based flame retardants are added - under high temperature, a dense carbonized layer quickly forms on the core surface, blocking the transmission of oxygen and heat. It also inhibits the release of toxic gases (such as cyanides), improving combustion performance.

 

Fire protection enhancement of surface layer (dual protection)Inner layer (airflow side): Fire-resistant coated aluminum foil prevents high-temperature airflow from directly burning the core material.Outer layer (protective side): Coated aluminum foil or galvanized steel plates are used to delay outer layer softening and ensure duct structural integrity.

 

Fire protection design of connection structure (optimization of key weak points)Joint sealing: Fire-resistant sealants (e.g., silicone fire sealants) are used to fill joint gaps instead of ordinary sealants, preventing flames from penetrating through joints.Flange connection: Aluminum alloy flanges are used to ensure no loosening or gaps at flange connections under high temperature, preventing flame spread caused by longitudinal cracking of ducts.

 

Technical  Date

 

Property Unit Specification
Standard Size mm 3950*1200*20
Foam Density kg/m³ 50-55
Aluminum Foil Thickness micron 60/80
Thermal Conductivity W/m.K 0.02
Fire Rating - BS 476 Part 6&7 Class 0  GB 8624 B1(B-s3,d0)
Compressive Strength Mpa 0.25
Bending Strength Mpa 2
Water Absorption % 0.1
Dimension Change % 0.3
Maximum Wind Velocity m/s 13-20
Maximum Running Temperature ℃ 80

 

Main Production Process of PIR Foam Pre-insulated Aluminum Duct

Raw Material Mixing
1. Raw Material Mixing
Aluminum Foil Embossing
2. Aluminum Foil Embossing
PU Foam Injection
3. PU/pIR Foam Injection
Foaming and Laminating
4. foaming & Laminating
5 Cutting1
5. Pre-insulated duct Cutting
6 Stacking1
6. duct panel Auto-stacking
Packing of Pre-insulated Duct
7. Packing of Pre-insulated Duct
8 Stocking1
8. Stocking of pre-insulated duct

 

 

Specification of PIR Pre-insulated Aluminum Duct for HVAC Duct System

 

Item

Unit

Specification

Panel Structure

 

Alu./Foam/Alu.

Standard Panel Size

mm

3950*1200*20

Alu. Foil Thickness

mm

0.06

Foam Density

kg/m3

48

Thermal Conductivity

w/m.k

0.022

Compressing Strength

Mpa

0.2

Bending Strength

Mpa

2

Water Absorption

%

0.36

Dimension Change

%

0.3

Working Temperature

℃

-100 to +80

Maximum Allowable Wind Velocity

m/s

≤12

Continuous Running Maximum Temperature

℃

≤70

Lifespan of PU Air Duct

years

>20