Thanks to its excellent products and quality services, UNT Duct is one of the leading pir pid panels manufacturers and suppliers in China. Welcome to buy the high quality and customized products from our factory. We will offer you the best service and fast delivery.
PIR PID Panels
PIR PID Panels feature a rigid polyisocyanurate foam core sandwiched between metal or fabric facings, offering superior thermal insulation (λD as low as 19 mW/m·K), excellent fire resistance (up to 60 minutes). The panel combines thermal insulation, lightweight construction and fabrication efficiency for pre-insulated HVAC ductwork.
Structure: Silver Aluminum/ PIR Foam/ Silver Aluminum
Size: 3950*1200*20mm
Foam Density: 50-55kg/m3
Aluminum Thickness: 0.06mm or 0.08mm
Aluminum Color: Silver
Packing: 10 sheets/ package
Loading Capacity: 710 sheets/ 40'HQ (packed with plastic bags)
660 sheets/ 40'HQ (packed with cardboard box)

Core Advantage of PIR PID Panels

PIR PID Panels are what sets this panel apart-it delivers performance that outperforms many traditional insulation materials. Its critical properties include:
Exceptional Thermal Insulation:
PIR foam has a lower thermal conductivity which means more thermal efficiency.
Closed-Cell Structure:
Unlike open-cell foams, PIR's closed cells trap air (and thus heat) and repel moisture. This prevents mold growth, corrosion, and insulation degradation over time.
Low Water Absorption:
The closed-cell PIR foam structure helps limit moisture absorption and maintain insulation performance in humid environments.
Fire Resistance:
PIR foam is inherently fire-retardant (meets standards such as ASTM E84, EN 13501-1). It self-extinguishes when exposed to flame and produces minimal toxic smoke-critical for HVAC safety (ducts act as "chimneys" in fires).
Applicable Scenarios and Industry Compatibility of PIR PID Panels
UNT PIR Pre-Insulated Duct Panels can be considered for HVAC systems where thermal insulation, weight, fabrication efficiency and fire performance are important project considerations.
Commercial HVAC
Suitable for air-conditioning and ventilation ductwork in commercial buildings, offices, shopping centres, hotels and other building services applications.
Data Centers
Can be considered for HVAC and air distribution systems in data center projects where thermal performance, installation efficiency and project-specific fire requirements need to be addressed.
Healthcare Facilities
Suitable for selected HVAC ductwork applications in hospitals, clinics and healthcare facilities, subject to project specifications, hygiene requirements and applicable standards.
Cleanrooms
Can be used in suitable cleanroom HVAC applications where the complete duct system is designed and installed according to the required cleanliness, sealing and environmental conditions.
Industrial HVAC
Suitable for selected industrial ventilation and air-conditioning systems where lightweight duct construction and integrated insulation are beneficial.
Other Building Services Applications
The PIR pre-insulated duct system can also be considered for other HVAC projects according to duct dimensions, pressure requirements, environmental conditions and applicable standards.

Why choose UNTDuct

Packaging of PIR Duct Board

Specification
|
Item |
Unit |
Specification |
|
Standard Panel Size |
mm |
3950x1200x20 |
|
Alu. Foil Thickness |
mm |
0.06 or 0.08 |
|
Foam Density |
kg/m³ |
50-55 |
|
Fire Safety (BS476Part 6&7) |
|
Class 0 |
|
Thermal Conductivity |
W/(m·K) |
0.020 |
|
Compressing Strength |
MPa |
0.2 |
|
Bending Strength |
MPa |
2 |
|
Water Absorption |
% |
0.36 |
|
Dimension Change |
% |
0.3 |
|
Working Temperature |
℃ |
-60 to +80 |
|
Max Pressure in duct |
Pa |
1500 |
|
Maximum Allowable Wind Velocity |
m/s |
≤15 |
|
Max Continuous Running Temperature |
℃ |
≤70 |
|
Lifespan of PIR Air Duct |
years |
>20 |
PRE-INSULATED DUCT vs G.I. DUCTWORK
|
Metric |
20mm PIR Pre - Insulated Duct |
0.5mm G.I Duct + 30mm Rubber Plastic (40-90kg/m3) |
|
Fire Safety |
Compliant (Class 0/BS 476, AS 1530.3). Self-extinguishing PIR core, low toxic smoke, non-combustible alu foil. |
G.I non-combustible; |
|
Thermal Insulation |
Excellent. |
Fair. |
|
Hygiene & Air Quality |
Superior. |
Poor. |
|
Lightweight |
1.4-1.5 kg/m². |
5.1–6.3 kg/m². |
|
Energy Efficiency |
Excellent. |
Low. |
|
Ease of Construction |
Easy. |
Complex. |
|
Quiet Operation |
Good. |
Fair. |
|
Space Savings |
Excellent. |
Poor. |
|
Environmental Friendliness |
Balanced. |
Low. |
|
Air Leakage |
Superior. |
Poor. |
Performance comparison based on UNT Duct product data and standard system configurations. Actual performance may vary depending on system design, installation method and project conditions.
How To Make PIR Pre-insulated Straight Duct
Step 1 - Tracing: outline the duct shapes on the panel.
Step 2 - Cutting: Using manual cutting tools, cut along the panel edges and create 90 degree "V" grooves on the panel.
Step 3 - Gluing: Apply glue to the cutting surfaces of the panels.
Step 4 - Folding: After the glue is cured, fold the sides toward each other to form the straight duct.
Step 5 - Taping: The tape is applied only to the external seams of the duct where the sides of the panel were joined for air-tightness.
Step 6 - Flanging: After applying glue and positioning the steel angle bracket, process to fit the PVC or aluminum invisible flanges.
Step 7 - Reinforcement: reinforce the duct with an aluminum reinforcement bar and G.I. Shaped disks, if necessary.
Step 8 - Sealing: After the duct is assembled, seal all internal joints hermetically with silicone.
Need the complete fabrication solution?
UNT Duct supplies PIR duct panels, fabrication tools, jointing accessories, reinforcement components and related materials for complete pre-insulated duct fabrication.

Hot Tags: pir pid panels, China, suppliers, manufacturers, factory, customized